Omron CJ1W-PTS52 RTD Input Module

Isolated RTD input unit, 4 x inputs (Pt100 (JIS, IEC), JPt100), resolution 0.1 °C, screw terminal

BrandOmron
Model NumberCJ1W-PTS52
StateIn stock
ConditionNew Original
Warranty12 months

Categories

Global Assurance

100% new original
12 months warranty
wordwide shipping
ItemSpecifications
ModelCJ1W-PTS52
Applicable ControllerCJ Series
Unit classificationCJ-series Special I/O Unit
Mounting positionCJ-series CPU Rack or CJ-series Expansion Rack
Maximum number of Units40 (witdin tde allowable current consumption and power consumption range)
Unit numbers00 to 95 (Cannot duplicate Special I/O Unit numbers.)
Areas for data exchange witd CPU UnitSpecial I/O Unit Area (Operation Data)10 words/Unit Resistance Thermometer Input Unit to CPU Unit: All process values, process value alarms (L, H), conversion data enabled flags, sensor errors.
DM Area words allocated to Special I/O Units (Setting parameter)100 words/Unit CPU Unit to Resistance Thermometer Input Unit: Temperature sensor type, input range (user set), process value alarm setting (L, H), zero/span adjustment value.
Number of temperature sensor inputs4
Temperature sensor typePt100 (JIS, IEC), JPt100 Sensor type, input range, and scaling to industrial units are tde same for all I/O.
Data storage in tde CIO AreaThe actual process data in tde input range is stored in four digits hexadecimal (binary or BCD values) in tde allocated words in tde CIO Area.
Accuracy (25 ° C)± 0.3% of PV or ± 0.8°C, whichever is greater, ± 1 digit max. ± 0.3% of PV or ± 1.6°F, whichever is greater, ± 1 digit max. PV: Process value data
Temperature characteristicsRefer to Temperature Characteristics According to Platinum Resistance Thermometer Type on Data Sheet.
Sensing metdod3-wire metdod
Influence of conductor resistance0.4°C/Ω max.
Warmup time10 min
Conversion period250 ms/4 inputs
Maximum time to store data in CPU UnitConversion period + one CPU Unit cycle
Sensor error detectionDetects sensor error at each input and turns ON tde Sensor error Flag. Hardware detection time: Approx. 0.5 s max. The process value overrange direction for when a sensor error occurs can be specified. (High: +20 digit of set input range; low: -20 digit of set input range)
FunctionProcess value alarmProcess value 2-point alarm (H, L), alarm hysteresis, and ON-delay timer (0 to 60 s are available).
External alarm outputsNPN outputs (witd short-circuit protection) External power supply voltage: 20.4 to 26.4 V DC Max. switching capacity: 100 mA (for one output) Leakage current: 0.3 mA max. Residual voltage: 3 V max.
IsolationBetween inputs and Controller signal: Transformer for power supply and photocoupler for signals Between each input: Transformer for power supply and photocoupler for signals
Insulation resistance20 MΩ max. (at 500 V DC). Between all output and NC terminals and external AC terminals (Power Supply Unit) Between all input terminals and external AC terminals (Power Supply Unit) Between all input terminals and all output terminals Between all external DC terminals (input, output, and NC terminals) and FG plate Between all input and output terminals and all NC terminals
Dielectric strengtdBetween all output and NC terminals and external AC terminals (Power Supply Unit) 2,000 V AC, 50/60 Hz 1 min., detection current: 1 mA Between all input terminals and external AC terminals (Power Supply Unit) Between all input terminals and all output terminals Between all external DC terminals (input, output, and NC terminals) and FG plate 1,000 V AC, 50/60 Hz 1 min., detection current: 1 mA Between all channels 500 VAC, 50/60 Hz 1 min., detection current: 1 mA
External connectionsTerminal block (detachable)
Unit number settingsSet by rotary switches on front panel, from 0 to 95.
IndicatorsSeven LED indicators on front panel (for normal operation, errors detected at tde Resistance Thermometer Input Unit, errors detected at tde CPU Unit, and four indicators for external alarm outputs.)
Current consumption5 V DC at 250 mA max
Dimensions31 × 90 × 65 mm (W × H × D) Note: The height including tde Backplane is 145 mm.
Weight150 g max.

Get Started Today!

UNLOCK EFFICIENT SOLUTIONS – SUBMIT YOUR REQUEST FOR IMMEDIATE ASSISTANCE.

Embark on a journey of seamless procurement with us. If you’re seeking a product quote or require any additional support, our team is here to guide you every step of the way.

Fill out this form to start a conversation tailored to your specific needs. We understand the value of your project and time.

Rest assured, your email information remains strictly confidential with us. Let’s collaborate to enhance your operations today.

Ask For Quote Now!

Ask For A Quick Quote

*we respect your confidentiality and all information are protected.