Brand | Delta |
Model Number | ASD-B2-1521-B |
State | In stock |
Condition | New Original |
Warranty | 12 months |
Categories
- Delta
- Delta ASDA-B2 Servo Drive
Global Assurance
Model: ASD-B2 Series | 100W | 200W | 400W | 750W | 1kW | 1.5kW | 2kW | 3kW | ||
01 | 02 | 04 | 07 | 10 | 15 | 20 | 30 | |||
Torque Control Mode | Analog Input Command | Voltage Range | 0 ~ ±10 VDC | |||||||
Input Resistance | 10KW | |||||||||
Time Constant | 2.2 us | |||||||||
Command Source | External analog signal / Internal parameters | |||||||||
Smoothing Strategy | Low-pass filter | |||||||||
Speed Limit Operation | Parameter Setting or via Analog input | |||||||||
Analog Monitor Output | Monitor signal can set by parameters (Output voltage range: ±8V) | |||||||||
Digital Inputs/Outputs | Inputs | Servo On, Reset, Gain switching, Pulse clear, Zero speed CLAMP, Command input reverse control, Speed/Torque limit enabled, Speed command selection, Position / Speed mode switching, Speed / Torque mode switching, Torque / Position mode switching, Emergency stop, Forward / Reverse inhibit limit, Forward / Reverse operation torque limit, Forward / Reverse JOG input, Electronic gear ratio (Numerator) selection and Pulse inhibit input | ||||||||
Outputs | Encoder signal output (A, B, Z Line Driver / Z Open collector) | |||||||||
Servo ready, Servo On, At Zero speed, At Speed reached, At Positioning completed, At Torques limit, Servo alarm (Servo fault) activated, Electromagnetic brake control, Output overload warning, Servo warning activated | ||||||||||
Protective Functions | Overcurrent, Overvoltage, Undervoltage, Motor overheated, Overload, Overspeed, Excessive deviation, Regeneration error, Abnormal pulse control command, Encoder error, Adjustment error, Emergency stop activated, Reverse/ Forward limit switch error, IGBT temperature error, Serial communication error, Input power phase loss, Serial communication time out, terminals with short circuit protection (U, V ,W , CN1, CN2, CN3 terminals) | |||||||||
Communication Interface | RS-232/RS-485 | |||||||||
Environment | Installation Site | Indoor location (free from direct sunlight), no corrosive liquid and gas (far away from oil mist, flammable gas, dust) | ||||||||
Altitude | Altitude 1000m or lower above sea level | |||||||||
Atmospheric pressure | 86kPa to 106kPa | |||||||||
Operating Temperature | 0oC to 55oC (32°F to 131°F) (If operating temperature is above specified range, forced cooling will be required) | |||||||||
Storage Temperature | -20℃ ~ 65℃ | |||||||||
Humidity | 0 to 90% (non-condensing) | |||||||||
Vibration | 2 2 9.80665m/s (1G) less than 20Hz, 5.88m/ s (0.6G) 20 to 50Hz | |||||||||
IP Rating | IP20 | |||||||||
Power System | TN System *4 | |||||||||
Standards/Requirement | IEC/EN 61800-5-1, UL 508C |
Related Product
Get Started Today!
UNLOCK EFFICIENT SOLUTIONS – SUBMIT YOUR REQUEST FOR IMMEDIATE ASSISTANCE.
Embark on a journey of seamless procurement with us. If you’re seeking a product quote or require any additional support, our team is here to guide you every step of the way.
Fill out this form to start a conversation tailored to your specific needs. We understand the value of your project and time.
Rest assured, your email information remains strictly confidential with us. Let’s collaborate to enhance your operations today.