Delta Servo Drive ASD-A0721-AB

Servo drive from the ASD-A series, AC Servo Drive, Power Voltage : 700w, ensuring smooth and efficient motion control in various industrial tasks.

Brand Delta
Model Number ASD-A0721-AB
State In stock
Condition New Original
Warranty 12 months

Categories

Global Assurance

100-new-original
12-months-warranty
worldwide-shipping
Model: ASD-A 100W 200W 400W 100W 200W 400W 750W 1kW 1.5kW 2kW 3kW
01 02 04 01 02 04 07 10 15 20 30
Power supply     Phase / Voltage None Three-phase: 170~255VAC, 50 / 60Hz ±5%   Three-phase 170~255VAC, 50 / 60Hz ±5%
Single-phase: 100 -10% ~ 115 +10% VAC, 50 / 60Hz ±5%   Single-phase: 200~255VAC, 50 / 60Hz ±5%
Continuous Output Current 2.0 Arms 3.4 Arms 6.2 Arms 0.8 Arms 1.3 Arms 2.6 Arms 4.7 Arms 6.2 Arms 8.0 Arms 9.1 Arms 13.6 Arms
Cooling System Natural Air Circulation Fan Cooling
Encoder Resolution / Feedback Resolution 2500ppr / 10000ppr
Control of Main Circuit SVPWM Control
Tuning Modes Auto / Manual
Dynamic Brake Built-in
Position Control Mode Max. Input Pulse Frequency Max. 500Kpps (Line driver) / Max. 200Kpps (Open collector)
Pulse Type Pulse + Direction, A phase + B phase, CCW pulse + CW pulse
Command Source External pulse train / Internal parameters
Smoothing Strategy Low-pass and P-curve filter
Electronic Gear Electronic gear N/M multiple N: 1~32767, M: 1:32767(1/50<N/M<200)
Torque Limit Operation Set by parameters
Feed Forward Compensation Set by parameters
Speed Control Mode     Analog Input Command   Voltage Range 0 ~ ±10 VDC
Input Resistance 10KW
Time Constant 2.2 ms
Speed Control Range*1 1:5000
Command Source External analog signal / Internal parameters
Smoothing Strategy Low-pass and S-curve filter
Torque Limit Operation Set by parameters or via Analog input
Responsiveness Characteristic Maximum 450Hz
Speed Fluctuation Rate*2 0.01% or less at load fluctuation 0 to 100% (at rated speed)
0.01% or less at power fluctuation ±10% (at rated speed)
o o 0.01% or less at ambient temperature fluctuation 0 C to 50 C(at rated speed)
Model: ASD-A 100W 200W 400W 100W 200W 400W 750W 1kW 1.5kW 2kW 3kW
01 02 04 01 02 04 07 10 15 20 30
Torque Control Mode      Analog Input Command   Voltage Range 0 ~ ±10 VDC
Input Resistance 10KW
Time Constant 2.2 ms
Command Source External analog signal / Internal parameters
Smoothing Strategy Low-pass filter
Speed Limit Operation Parameter Setting or via Analog input
Analog Monitor Output Monitor signal can set by parameters (Output voltage range: ±8V)
         Digital Input/Output      Input Servo On, Reset, Gain switching, Pulse clear, Zero speed CLAMP, Speed/Torque limit enabled, Emergency stop, Forward / Reverse inhibit limit, Position / Speed mode switching, Speed / Torque mode switching, Torque / Position mode switching, Feed step selection input, Feed step mode input, Auto run input, Electronic gear ratio (Numerator) selection
     Output   Encoder signal output (A, B, Z Line Driver / Z Open collector)
Servo ready, Servo On, At Zero speed, At Speed reached, At Positioning completed, At Torques limit, Servo alarm (Servo fault) activated, Electromagnetic brake control, Homing completed, Output overload warning  Servo warning activated, Internal position command completed
       Protective Functions Overcurrent, Overvoltage, Undervoltage, Regeneration error, Overload, Overspeed, Abnormal pulse control command, Excessive deviation, Watch dog execution time out, Encoder error, Adjustment error, Emergency stop activated, Reverse/ Forward limit switch error, IGBT temperature error, Memory error, DSP communication error, Serial communication error, Input power phase loss, Serial communication time out, Command write-in error, terminals with short circuit protection (U, V ,W , CN1, CN2, CN3 terminals)
Communication Interface RS-232 / RS-485 / RS-422
Environment Installation Site Indoor location (free from direct sunlight), no corrosive liquid and gas (far away from oil mist, flammable gas, dust)
Altitude Altitude 1000m or lower above sea level
Atmospheric pressure 86kPa to 106kPa
Operating Temperature o o  0 C to 55 C (32°F to 131°F) (If operating temperature is above specified range, forced cooling will be required)
Storage Temperature o o  -20 C to 65 C (-4°F to 149°F)
Humidity 0 to 90% (non-condensing)
Vibration 2 2  9.80665m/s (1G) less than 20Hz, 5.88m/ s (0.6G) 20 to 50Hz
IP Rating IP20
Power System TN System*3
 Standards/Requirement IEC/EN 61800-5-1, UL 508C, C-tick, TUV

Get Started Today!

UNLOCK EFFICIENT SOLUTIONS – SUBMIT YOUR REQUEST FOR IMMEDIATE ASSISTANCE.

Embark on a journey of seamless procurement with us. If you’re seeking a product quote or require any additional support, our team is here to guide you every step of the way.

Fill out this form to start a conversation tailored to your specific needs. We understand the value of your project and time.

Rest assured, your email information remains strictly confidential with us. Let’s collaborate to enhance your operations today.

Ask For Quote Now!

Ask For A Quick Quote

*we respect your confidentiality and all information are protected.