Digital input module, 16 digital inputs, suitable for the NX series PLCs.

  • High Input Capacity: 16 NPN input points for extensive monitoring.
  • Fast Response: ON/OFF response time of 20 μs for rapid signal processing.
  • Compact Design: Measures 12 x 100 x 71 mm, optimizing space utilization.
  • Wide Operating Range: Suitable for temperatures from 0 to 55°C.
  • Reliable Communication: EtherCAT support ensures fast and robust data transfer.
  • Compliance: Meets CE, UL, and RoHS standards for safety and environmental requirements.

Categories

Global Assurance

100% new original
12 months warranty
wordwide shipping
Unit name DC Input Unit Model NX-ID5342
Number of points 16 points External connection terminals Screwless clamping terminal block (16 terminals)
I/O refreshing method Selectable Synchronous I/O refreshing or Free-Run refreshing
Indicators TS indicator, input indicator
3185_sp_10_1
Internal I/O common NPN
Rated input voltage 24 VDC (15 to 28.8 VDC)
Input current 3.5 mA typical (at 24 VDC), rated current
ON voltage/ON current 15 VDC min./2 mA min. (between IOG and each signal)
OFF voltage/OFF current 5 VDC max./0.5 mA max. (between IOG and each signal)
ON/OFF response time 20 μs max./400 μs max.
Input filter time Without filter, 0.25 ms, 0.5 ms, 1 ms (factory setting), 2 ms, 4 ms, 8 ms, 16 ms, 32 ms, 64 ms, 128 ms, 256 ms
Dimensions 12 (W) x 100 (H) x 71 (D) Isolation method Photocoupler isolation
Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC) Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max.
I/O power supply method Supply from the NX bus Current capacity of I/O power supply terminal Without I/O power supply terminals
NX Unit power consumption • Connected to a CPU Unit or Communication Control Unit 0.90 W max. • Connected to a Communi- cations Coupler Unit 0.55 W max. Current consumption from I/O power supply No consumption
Weight 65 g max.
Circuit layout
3185_sp_10_2
Installation orientation and restrictions Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions
Terminal connection diagram
3185_sp_10_3
Disconnection/ Short-circuit detection Not supported. Protective function Not supported.

Get Started Today!

UNLOCK EFFICIENT SOLUTIONS – SUBMIT YOUR REQUEST FOR IMMEDIATE ASSISTANCE.

Embark on a journey of seamless procurement with us. If you’re seeking a product quote or require any additional support, our team is here to guide you every step of the way.

Fill out this form to start a conversation tailored to your specific needs. We understand the value of your project and time.

Rest assured, your email information remains strictly confidential with us. Let’s collaborate to enhance your operations today.

Ask For Quote Now!

Ask For A Quick Quote

*we respect your confidentiality and all information are protected.

Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.