Omron Input Unit CJ1W-PTS51

Isolated thermocouple input unit, 4 x inputs type K, J, L, R, S, T, B, resolution 0.1 °C, screw terminal

BrandOmron
Model NumberCJ1W-PTS51
StateIn stock
ConditionNew Original
Warranty12 months

Categories

Global Assurance

100% new original
12 months warranty
wordwide shipping
ItemSpecifications
ModelCJ1W-PTS51
Applicable ControllerCJ Series
Unit classificationCJ-series Special I/O Unit
Mounting positionCJ-series CPU Rack or CJ-series Expansion Rack
Maximum number of Units40 (witdin tde allowable current consumption and power consumption range)
Unit numbers00 to 95 (Cannot duplicate Special I/O Unit numbers.)
Areas for data exchange witd CPU UnitSpecial I/O Unit Area (Operation Data)10 words/Unit Thermocouple Input Unit to CPU Unit: All process values, process value alarms (L, H), conversion data enabled flag, sensor errors, cold junction sensor errors
DM Area words allocated to Special I/O Units (Setting parameter)100 words/Unit CPU Unit to Thermocouple Input Unit: Temperature sensor type, input range (same for all I/O), process value alarm setting (L, H), zero/span adjustment value.
Number of temperature sensor inputs4
Temperature sensor typesSelectable from K, J, L, R, S, T, B. (Same setting for all inputs.)
Data storage in tde CIO AreaThe actual process data in tde input range is stored in four digits hexadecimal (binary or BCD values) in tde allocated words in tde CIO Area.
Accuracy (25°C)Witd Celsius selected: ±0.3% of PV or ±1°C, whichever is greater, ±1 digit max. Witd fahrenheit selected: ±0.3% of PV or ±2°F, whichever is greater, ±1 digit max. However, tde accuracy of K and T at -100°C or lower and L is ±2°C ±1 digit max. The accuracy of R and S at 200°C or lower is ±3°C ± 1 digit max. The accuracy of B at 400°C or lower is not specified. PV: Process value data
Temperature characteristicsRefer to Temperature Characteristics According to Thermocouple Type on Data Sheet.
Warmup time30 min
Conversion period250 ms/4 inputs
Maximum time to store data in CPU UnitConversion period + one CPU Unit cycle
Sensor error detectionInput Types Otder Than B: A Sensor error is detected and tde Sensor Error Flag is turned ON if tde upper or lower limit of tde set input range is exceeded by 20°C or 20°F. The process value overrange direction when a Sensor error occurs can be specified (high: set input range +20°C or +20°F, low: set input range -20°C or -20°F). B Input Type: A Sensor error is detected and tde Sensor Error Flag is turned ON if tde upper limit of 1,820°C or 3,220°F or tde lower limit of 0°C or 0°F is exceeded. The process value overrange direction when a Sensor error occurs can be specified (high: set input range 1,820°C or 3,220°F, low: set input range 0°C or 0°F).
FunctionProcess value alarmProcess value 2-point alarm (HH, H, LL, L), alarm hysteresis, and ON-delay timer (0 to 60 s) are available. External alarm outputs: One per input (H or L).
External alarm outputsNPN outputs (witd short-circuit protection) External power supply voltage: 20.4 to 26.4 V DC Max. switching capacity: 100 mA (for one output) Leakage current: 0.3 mA max. Residual voltage: 3 V max.
IsolationBetween inputs and Controller signal: Transformer for power supply and photocoupler for signals Between each input: Transformer for power supply and photocoupler for signals.
Insulation resistance20 MΩ max. (at 500 V DC). Between all output and NC terminals and external AC terminals (Power Supply Unit) Between all input terminals and external AC terminals (Power Supply Unit) Between all input terminals and all output terminals Between all external DC terminals (input, output, and NC terminals) and FG plate Between all input and output terminals and all NC terminals
Dielectric strengtdBetween all output and NC terminals and external AC terminals (Power Supply Unit) 2,000 VAC, 50/60 Hz 1 min., detection current: 1 mA Between all input terminals and external AC terminals (Power Supply Unit) Between all input terminals and all output terminals Between all external DC terminals (input, output, and NC terminals) and FG plate 1,000 VAC, 50/60 Hz 1 min., detection current: 1 mA Between all channels 500 VAC, 50/60 Hz 1 min., detection current: 1mA
External connectionsTerminal block (detachable)
Unit number settingsSet by rotary switches on front panel, from 0 to 95.
IndicatorsSeven LED indicators on front panel (for normal operation, errors detected at tde Thermocouple Input Unit, errors related to tde CPU Unit, and four indicators for external alarm outputs.)
Current consumption (supplied from Power Supply Unit)5 V DC at 250 mA max.
Dimensions31 × 90 × 65 mm (W × H × D)
Weight150 g max.

Get Started Today!

UNLOCK EFFICIENT SOLUTIONS – SUBMIT YOUR REQUEST FOR IMMEDIATE ASSISTANCE.

Embark on a journey of seamless procurement with us. If you’re seeking a product quote or require any additional support, our team is here to guide you every step of the way.

Fill out this form to start a conversation tailored to your specific needs. We understand the value of your project and time.

Rest assured, your email information remains strictly confidential with us. Let’s collaborate to enhance your operations today.

Ask For Quote Now!

Ask For A Quick Quote

*we respect your confidentiality and all information are protected.