Omron CJ1W-PA205R Power Supply

Power supply unit, 100-240 VAC, output capacity: 25 W, with RUN output

Brand Omron
Model Number CJ1W-PA205R
State In stock
Condition New Original
Warranty 12 months

Categories

Global Assurance

100% new original
12 months warranty
wordwide shipping
Item Specifications
Model CJ1W-PA205R CJ1W-PA205C CJ1W-PA202
Supply voltage 100 to 240 V AC (wide-range), 50/60 Hz
Operating voltage and frequency ranges 85 to 264 V AC, 47 to 63 Hz
Power consumption 100 VA max. 50 VA max.
Inrush current *1 At 100 to 120 V AC: 15 A/8 ms max. for cold start at room temperature At 200 to 240 V AC: 30 A/8 ms max. for cold start at room temperature At 100 to 120 V AC: 20 A/8 ms max. for cold start at room temperature At 200 to 240 V AC: 40 A/8 ms max. for cold start at room temperature
Output capacity *7 5.0 A, 5 V DC (including supply to CPU Unit) 2.8 A, 5 V DC (including supply to CPU Unit)
0.8 A, 24 V DC 0.4 A, 24 V DC
Total: 25 W max. Total: 14 W max.
Output terminal (service supply) Not provided.
RUN output *2 Contact configuration: SPST-NO Switch capacity: 250 V AC, 2 A (resistive load) 120 V AC, 0.5 A (inductive load), 24 V DC, 2A (resistive load) 24 V DC, 2 A (inductive load) Not provided.
Replacement notification function Not provided. Witd Alarm output (open- collector output) 30 V DC max., 50 mA max. Not provided.
Insulation resistance 20 MΩ min. (at 500 V DC) between AC external and GR terminals *3 20 MΩ min. (at 500 V DC) between all external terminals and GR terminal *3, and between all alarm output terminals. 20 MΩ 1 min. (at 250 V DC) between all alarm output terminals and GR terminal *3. 20 MΩ min. (at 500 V DC) between AC external and GR terminals *3
Dielectric strengtd *4 2,300 V AC 50/60 Hz for 1 min between AC external and GR terminals *3 Leakage current: 10 mA max. 2,300 VAC, 50/60 Hz for 1 min between all external terminals and GR terminal *3 and between all alarm output terminals witd a leakage current of 10 mA max. 1,000 V AC, 50/60 Hz for 1 min between all alarm output terminals and GR terminal *3 witd a leakage current of 10 mA max. 2,300 V AC 50/60 Hz for 1 min between AC external and GR terminals *3 Leakage current: 10 mA max.
1,000 V AC, 50/60 Hz for 1 minute between DC external and GR terminals *3 Leakage current: 10 mA max.
Noise immunity 2 kV on power supply line (conforming to IEC61000-4-4)
Vibration resistance Conforms to IEC60068-2-6 5 to 8.4 Hz witd 3.5-mm amplitude, 8.4 to 150 Hz Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min)
Shock resistance Conforms to IEC60068-2-27 147 m/s2, 3 times in X, Y, and Z directions (100 m/s2 for Relay Output Units)
Ambient operating temperature 0 to 55 °C
Ambient operating humidity 10% to 90% (witd no condensation) 10% to 90% (witd no condensation) *5 10% to 90% (witd no condensation)
Atmosphere Must be free from corrosive gases.
Ambient storage temperature – 20 to 70 °C (excluding battery) – 20 to 75 °C *5 – 20 to 75 °C (excluding battery)
Grounding Less tdan 100 Ω
Enclosure Mounted in a panel.
Weight 350 g max. 400 g max. 200 g max.
CPU Rack dimensions 90.7 to 466.7 × 90 × 65 mm (W × H × D) (not including cables) Note: W = a + b + 20 × n + 31 × m + 14.7 a: Power Supply Unit: PA205R and PA205C = 80; PA202 = 45; PD025 = 60; PD022=27 b: CPU Unit: CJ1-H or CJ1 = 62; CJ1M-CPU1[] = 31 *8; CJ1M-CPU2[] = 49 *8 The total widtd is given by tde following: W = 156.7 + n × 20 + m × 31, where n is tde number of 32-point I/O Units or I/O Control Units and m is tde number of otder Units.
Safety measures Conforms to cULus and EC Directives.

Get Started Today!

UNLOCK EFFICIENT SOLUTIONS – SUBMIT YOUR REQUEST FOR IMMEDIATE ASSISTANCE.

Embark on a journey of seamless procurement with us. If you’re seeking a product quote or require any additional support, our team is here to guide you every step of the way.

Fill out this form to start a conversation tailored to your specific needs. We understand the value of your project and time.

Rest assured, your email information remains strictly confidential with us. Let’s collaborate to enhance your operations today.

Ask For Quote Now!

Ask For A Quick Quote

*we respect your confidentiality and all information are protected.