[gtranslate]

Omron Analog Output Unit CJ1W-DA08C

Analog output unit, 8 x outputs 4 to 20 mA, resolution 12 bit, screw terminal

BrandOmron
Model NumberCJ1W-DA08C
StateIn stock
ConditionNew Original
Warranty12 months

Categories

Global Assurance

100% new original
12 months warranty
wordwide shipping
ItemCJ1W-DA021CJ1W-DA041CJ1W-DA08VCJ1W-DA08CCJ1W-DA042V
Unit typeCJ-series Special I/O Unit
Isolation *1Between I/O and Controller signals: Photocoupler (No isolation between I/O signals.)Between I/O and Controller signals: Digital isolator (No isolation between I/O signals.)
External terminals18-point detachable terminal block (M3 screws)
Power consumption5 VDC, 120 mA max.5 VDC, 140 mA max.5 VDC, 400 mA max.
External power supply *224 VDC +10% -15%, (inrush current: 20 A max., pulse widtd: 1 ms min.)
140 mA max.200 mA max.140 mA max.170 mA max.
Dimensions (mm)31 × 90 × 65 mm (W × H × D)
Weight150 g max.
General specificationsConforms to general specifications for CJ-series Series.
Output specifi- cationsNumber of analog outputs24884
Output signal range *31 to 5 V/4 to 20 mA 0 to 5 V 0 to 10 V – 10 to 10 V1 to 5 V 0 to 5 V 0 to 10 V – 10 to 10 V4 to 20 mA1 to 5 V 0 to 10 V – 10 to 10 V
Output impedance0.5 Ω max. (for voltage output)0.5 Ω max. (for voltage output)0.5 Ω max. (for voltage output)
Max. output current (for 1 point)12 mA (for voltage output)2.4 mA (for voltage output)2 mA (for voltage output)
Maximum permissible load resistance600 Ω (current output)350 Ω
Resolution40,0004,000/8,000 *81 to 5 V10,000
0 to 10 V20,000
-10 to 10 V40,000
Set data16-bit binary data
Accuracy *425 °CVoltage output: ± 0.3% of F.S. Current output: ± 0.5% of F.S.± 0.3% of F.S.± 0.3% of F.S.± 0.3% of F.S.
0 °C to 55 °CVoltage output: ± 0.5% of F.S. Current output: ± 0.8% of F.S.± 0.5% of F.S.± 0.6% of F.S.± 0.5% of F.S.
D/A conversion period *51.0 ms per point1.0 ms or 250 μs per point *820 μs/1 point, 25 μs/2 points, 30 μs/3 points, 35 μs/4 points
Output functionsOutput hold functionOutputs tde specified output status (CLR, HOLD, or MAX) under any of tde following circumstances. When tde Conversion Enable Bit is OFF. *6 In adjustment mode, when a value otder tdan tde output number is output during adjustment. *7 When output setting value error occurs or Controller operation stops. When tde Load is OFF.
ScalingSupported only for a conversion period of 1 ms and resolution of 4,000. Setting values in any specified unit witdin a range of ± 32,000 as tde upper and lower limits allows D/A conversion to be executed and analog signals to be output witd tdese values as full scale.Setting values in any specified unit witdin a range of ±32,000 as tde upper and lower limits allows D/A conversion to be executed and analog signals to be output witd tdese values as full scale.
Offset/gain adjustmentSupported
Direct conversionD/A conversion is performed and tde output value is refreshed when tde ANALOG OUTPUT DIRECT CONVERSION instruction (AODC) is executed. This instruction is supported by tde CJ2H- CPU[][](-EIP) CPU Units witd unit version 1.1 or later, and CJ2M-CPU[][]. CJ1, NJ501, and CP1H CPU Units and NSJ Controllers do not support direct conversion.

Get Started Today!

UNLOCK EFFICIENT SOLUTIONS – SUBMIT YOUR REQUEST FOR IMMEDIATE ASSISTANCE.

Embark on a journey of seamless procurement with us. If you’re seeking a product quote or require any additional support, our team is here to guide you every step of the way.

Fill out this form to start a conversation tailored to your specific needs. We understand the value of your project and time.

Rest assured, your email information remains strictly confidential with us. Let’s collaborate to enhance your operations today.

Ask For Quote Now!

Ask For A Quick Quote

*we respect your confidentiality and all information are protected.