Omron E3X-NA41 Digital Fiber Amplifier
Foto 1 de 5 · Selecione a imagem principal para ampliar.
Vai substituir um amplificador existente?

Indique o modelo completo do amplificador e a referência da cabeça de fibra ótica ao solicitar uma cotação.

OMRON / FIBER AMPLIFIER

Omron E3X-NA41 PNP Fiber Amplifier

Standard fiber amplifier with PNP open-collector output, a pre-wired 2 m cable, an LED bar display and manual sensitivity adjustment.

Novo e original apenasGarantia KWOCO de 12 meses

Pedir orçamento por email

Orçamento normalmente enviado em 24 horas. Preço e prazo confirmados por email.

Usamos os seus dados para responder a este pedido. Política de privacidade ↗

E3X-NA41 specifications

ModeloOmron E3X-NA41
SérieE3X-NA
TipoStandard fiber amplifier
SaídaColetor aberto PNP
Fonte de energia12–24 VDC ±10%, ondulação máxima de 10% pico a pico
ConexãoPre-wired, standard 2 m cable
OperaçãoLight-ON / Dark-ON selecionável
Fonte de luzLED vermelho
MostrarLED bar display
AdjustmentManual sensitivity adjuster
DoençaProduto novo e original
GarantiaGarantia KWOCO de 12 meses

Check the amplifier and fiber head together

E3X-NA41 reads light from a compatible fiber head and switches a PNP output to the controller. The LED bar helps compare light levels during setup.

  • Input compatibility: verify the controller input accepts the PNP output.
  • Cable routing: check the fixed lead length against your installation.
  • Cabeça de fibra ótica: confirm the part number, mounting and sensing range.
  • Adjuster: set sensitivity with the real target in place.
  • Output mode: verify both target states at normal machine speed.

Omron E3X-SD / NA datasheet (PDF) ↗

Perguntas frequentes

Can I use E3X-NA11 instead?

E3X-NA11 has NPN output. E3X-NA41 has PNP output. Check the controller input and wiring before selecting either model.

Is E3X-NA41 the same as E3X-NA41F?

E3X-NA41 is the standard model. The F suffix identifies the separate high-speed variant. Match the complete model on the existing label.

How far can it detect?

Sensing distance depends on the compatible fiber head, target and installation. Check the range table for the exact combination.

What should I record before replacing the amplifier?

Record the fiber head model, wiring, sensitivity position and Light-ON or Dark-ON setting. Check switching with the real target after installation.