OMRON DC Input Unit NX-ID5342

Digital input module, 16 digital inputs, suitable for the NX series PLCs.

  • Elevata capacità di input: 16 NPN input points for extensive monitoring.
  • Risposta rapida: ON/OFF response time of 20 μs for rapid signal processing.
  • Design compatto: Measures 12 x 100 x 71 mm, optimizing space utilization.
  • Ampia gamma operativa: Adatto per temperature da 0 a 55°C.
  • Comunicazione affidabile: EtherCAT support ensures fast and robust data transfer.
  • Conformità: Meets CE, UL, and RoHS standards for safety and environmental requirements.

Categorie

Garanzia globale

100% nuovo originale
Garanzia di 12 mesi
spedizione in tutto il mondo
Nome dell'unitàUnità di ingresso CCModelloCodice articolo: NX-ID5342
Numero di punti16 puntiExternal connection terminalsScrewless clamping terminal block (16 terminals)
I/O refreshing methodSelectable Synchronous I/O refreshing or Free-Run refreshing
IndicatoriTS indicator, input indicator
3185_sp_10_1
I/O interno comuneNPN
Tensione di ingresso nominale24 VDC (15 to 28.8 VDC)
Corrente di ingresso3.5 mA typical (at 24 VDC), rated current
Tensione ON/corrente ON15 VDC min./2 mA min. (between IOG and each signal)
OFF voltage/OFF current5 VDC max./0.5 mA max. (between IOG and each signal)
ON/OFF response timeMassimo 20 μs/massimo 400 μs.
Tempo di filtro di inputWithout filter, 0.25 ms, 0.5 ms, 1 ms (factory setting), 2 ms, 4 ms, 8 ms, 16 ms, 32 ms, 64 ms, 128 ms, 256 ms
Dimensioni12 (W) x 100 (H) x 71 (D)Metodo di isolamentoIsolamento fotoaccoppiatore
Insulation resistance20 MΩ min. between isolated circuits (at 100 VDC)Rigidità dielettrica510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max.
I/O power supply methodSupply from the NX busCurrent capacity of I/O power supply terminalSenza terminali di alimentazione I/O
NX Unit power consumption• Connected to a CPU Unit or Communication Control Unit 0.90 W max. • Connected to a Communi- cations Coupler Unit 0.55 W max.Current consumption from I/O power supplyNessun consumo
Peso65 g max.
Disposizione del circuito
3185_sp_10_2
Installation orientation and restrictionsInstallation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions
Terminal connection diagram
3185_sp_10_3
Disconnection/ Short-circuit detectionNon supportato.Funzione protettivaNon supportato.

Inizia oggi stesso!

SBLOCCA SOLUZIONI EFFICIENTI – INVIA LA TUA RICHIESTA PER ASSISTENZA IMMEDIATA.

Intraprendi con noi un viaggio di approvvigionamento senza intoppi. Se stai cercando un preventivo per un prodotto o necessiti di ulteriore supporto, il nostro team è qui per guidarti in ogni fase del percorso.

Compila questo modulo per avviare una conversazione su misura per le tue esigenze specifiche. Comprendiamo il valore del tuo progetto e del tuo tempo.

Non preoccuparti, le tue informazioni e-mail rimangono strettamente riservate con noi. Collaboriamo per migliorare le tue operazioni oggi stesso.

Richiedi un preventivo adesso!

Richiedi un preventivo veloce

*Rispettiamo la tua riservatezza e tutte le informazioni sono protette.